RHEEM - RGPH 10EBRJR (User Manual) User Manual RHEEM RGPH 10EBRJR - This User Manual - also called owner's manual or operating instructions - contains all information for the user to make full use of the product. This manual includes a description of the functions and capabilities and presents instructions as step-by-step procedures.
- Rheem Rgph-10eamer Df5d302f419602506 User Manual Download
- Rheem Rgph-10eamer Df5d302f419602506 User Manual 2017
- Rheem Rgph-10eamer Df5d302f419602506 User Manual Guide
Advertising
FORM NO. G11-449 REV. 6
Supersedes Form No. G11-449 Rev. 5
GAS FURNACES
CRITERION
®
II
80.0-82.2% A.F.U.E.
✝
![Rheem rgph-10eamer df5d302f419602506 user manual 1 Rheem rgph-10eamer df5d302f419602506 user manual 1](/uploads/1/2/6/0/126067708/543022173.jpg)
DOWNFLOW
GAS FURNACES
GAS FURNACES
The Rheem
®
Criterion
®
II line of downflow gas furnaces is
designed for installation in closets, alcoves, utility rooms, or
attics. The design is certified by CSA.
attics. The design is certified by CSA.
Features
■
Patented heat exchanger, constructed of both stainless
and aluminized steel for the maximum in corrosion
resistance.
and aluminized steel for the maximum in corrosion
resistance.
■
Low profile “34 inch” [864 mm] design is lighter and easier
to handle, and leaves room for optional equipment.
to handle, and leaves room for optional equipment.
■
Left or right side gas and electric inlet connections with
quick, simple change.
quick, simple change.
■
Direct Spark ignition models and integrated board with
humidifier and electronic air cleaner hookups.
humidifier and electronic air cleaner hookups.
■
Insulated blower compartment helps to reduce jacket loss
and noise.
and noise.
■
Pre-paint galvanized steel cabinet.
■
Molded permanent filter.
■
Grab-holes in doors to aid in easy door removal and
replacement.
replacement.
A variety of cooling coils and plenums designed to use with
Rheem Criterion II gas furnaces are available as optional
accessories.
Rheem Criterion II gas furnaces are available as optional
accessories.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
RGLH- SERIES
Models with Input Rates from
50,000 to 150,000 BTU/HR
[15 to 44 kW]
50,000 to 150,000 BTU/HR
[15 to 44 kW]
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
Rheem Rgph-10eamer Df5d302f419602506 User Manual Download
ENER UIDE
97%
78%
Rheem Rgph-10eamer Df5d302f419602506 User Manual 2017
HIGH
MID
82%
88%
80.0%